Gait & Posture
Volume 25, Issue 2 , Pages 303-315, February 2007

Increasing the number of gait trial recordings maximises intra-rater reliability of the CODA motion analysis system

School of Physiotherapy and Performance Science, Motion Analysis Laboratory, University College Dublin, Ireland

Received 19 December 2005; received in revised form 2 March 2006; accepted 14 April 2006. published online 26 May 2006.

Abstract 

Objective

This study investigates the optimum number of gait trial recordings to maximise intra-rater reliability with the CODA motion analysis system in a normal population. Potential sources of variability in test–retest experimental procedures will be discussed.

Background

The most recent study by [Maynard V, Bakheit AMO, Oldham J, Freeman J. Intra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system. Gait Posture 2003;17:59–67] that evaluated the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion analysis system exhibited poor correlation for intra-rater reliability of kinematic and kinetic parameters. It is unknown what the optimum number of gait trials is required during testing to represent an individuals gait pattern during normal walking.

Design

Ten healthy subjects (mean 28.5 years) were tested on two occasions by an experienced well trained rater during normal walking to establish intra-rater reliability using 1–2, 1–4, 1–6, 1–8, and 1–10 gait trial recordings to represent the mean. The 3D kinematic, kinetic parameters of hip, knee and ankle joints and spatio-temporal parameters were recorded during normal walking. Intra-class correlation coefficient and Bland and Altman limits of agreement were chosen to analyse the results.

Results

Spatio-temporal parameters exhibited least test–retest variability, as measurement of only two gait trials to represent the mean produced similar variability in test–retest as when higher numbers of trials were measured. Kinematic parameters were more variable than kinetic while for both variability decreased with increasing numbers of trials measured and would advocate measuring 10 gait trials for future analysis when measuring these parameters.

Conclusions

Generally intra-rater reliability improves when larger number of gait trial recordings represent a subject's gait.

Keywords: CODA, Intra-rater reliability, Kinematics, Kinetics, Spatio-temporal parameters

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0966-6362(06)00062-2

doi:10.1016/j.gaitpost.2006.04.011

Gait & Posture
Volume 25, Issue 2 , Pages 303-315, February 2007